Cables for these link segments must be certified as
EIA/TIA-568 Category 5.
ñ Cables that have been certified as EIA/TIA-568
Category 5 meet all 10BASE-T and 100BASE-TX
specifications. An EIA/TIA-568 Category 5 cable must
be used for 10BASE-T and 100BASE-TX.
ò The cable can contain two to four twisted pairs, but
only two of the pairs will be used by the 10BASE-T or
100BASE-TX network.
ó The c represents the velocity of light traveling in a
vacuum, which is 300 000 km/sec (186 400 mi/sec).
Table 1. Cabling Specifications for 10BASE-T and
100BASE-TX Link Segments
Characteristic Specificationñ
Cable type UTP cable with two twisted pairs
of 22, 24, or 26 AWGò wire
Nominal impedance 100 Ohms
Velocity of propagation 0.585 có
Maximum attenuation For 10BASE-T: 8 to 10 dB
per 100 m at 10 MHz
For 100BASE-TX: 67 dB
per 305 m at 100 MHz