intervention. The controller supports half-duplex (HDX)
and full-duplex (FDX) modes at both speeds.
However, auto-negotiation works only if the hub or switch
at the other end of the network also supports
auto-negotiation. If the hub or switch does not support
auto-negotiation, the speed (10 Mbps or 100 Mbps) will still
be detected correctly, but half-duplex mode will always be
selected. A full-duplex switch that does not support
auto-negotiation will not attach to the Netfinity 3500 server
in full-duplex mode. In this case, if you want the network
to operate in full-duplex mode, you must manually override
the settings to obtain a full-duplex connection. Refer to the
Ethernet documentation for additional information.
Attention
The 10BASE-T Ethernet and the 100BASE-TX
Fast Ethernet cabling in the network must be
Category 5 or higher to meet various standards,
including electromagnetic compatibility.
You must install a device driver to enable the
operating system to address the Ethernet
controller. Use ServerGuide to install this device
driver. Refer to the ServerGuide package for
instructions on installing device drivers.
Fast Ethernet operates at a data rate of 100 Mbps; that is,
ten times faster than standard Ethernet. However, except
for the different operating speeds, Fast Ethernet and
standard Ethernet are structurally identical. Applications
and protocols that are currently installed on a standard
Ethernet system can be seamlessly migrated to a Fast
Ethernet system. (In a very small number of cases, minor
tuning might be required to adjust the application to the
faster response time of a Fast Ethernet system.) Because
of the equivalence of the two types of Ethernet, mixed
Ethernet and Fast Ethernet systems also can be designed
and implemented.
The bandwidth required at each workstation connected to
a server is generally far less than the bandwidth required
at the server. This is because the server might have to
handle the bandwidth of multiple workstations at the same
time. A cost-effective solution to the bandwidth
requirements of this type of system is a mixed Ethernet
and Fast Ethernet network. This mixed network consists
of standard Ethernet connections at the workstations and
Fast Ethernet connections at the servers.
The Ethernet controller is a PCI device, and is therefore, a
Plug and Play device. You do not have to set any jumpers
or configure the controller for the operating system before
you use the Ethernet controller.
IBM Netfinity 3500 - Type 8644